Home Products News Contact Us
Home > Products > Controllers > Smartgen > HGM6100N Series Auto Start Controller
HGM6100N Series Auto Start Controller HGM6100N Series Auto Start Controller HGM6100N Series Auto Start Controller

HGM6100N Series Auto Start Controller

(HGM6110N/6120N/6110NC/6120NC/6110CAN/6120CAN)

Product Code: 6010042

Power Supply: DC(8-35)V

Case Dimensions: 209x 166 x 45(mm)

Panel Cutout: 186 x 141 (mm)

Operating Temp. : (-25~70)

Weight: 0.56kg

SmartGen HGM6110N Generator Set Controller

HGM6100N series automatic controller uses micro-processing technique which can achieve precision measurement, value adjustment, timing and threshold setting etc.. All the parameters can be configured from front panel or use USB interface (or RS485 interface) to adjust via PC. It can be widely used in all types of automatic control system for its compact structure, simple connections and high reliability.


HGM6110N/6110NC/6110CAN: Automatic Start Module, it controls generator to start/stop by remote start signal;


perkins smartgen cummins diesel generator


PERFORMANCE AND CHARACTERISTICS


1. 132*64 LCD display with backlight, optional language interface (Chinese, English, Spanish, Russian, Portuguese, Turkey, Polish and French), push-button operation;

2. Acrylic screen, improved wearable and scratch resistance property;

3. Silica-gel panel and keys can well adapt to higher and lower temperature;

4. With RS485 communication port, can achieve ―three remote functions via MODBUS protocol;

5. With CANBUS port which can be connected to electronic injection with J1939, it not only can monitor frequently-used data (such as water temperature, oil pressure, rotated speed and fuel consumption, etc.) but also can control start, stop, high speed and low speed (controller with CANBUS port isneeded) via CANBUS port.

6. Adapt to 3P4W, 3P3W, 1P2W and 2P3W (120V/240V), 50Hz/60Hz AC power system;

7. Can measure and display 3 phase voltage, 3 phase current, frequency, power parameter of mains/genset;


Mains                                           Generator

Line voltage (Uab, Ubc, and Uca)     Line voltage (Uab, Ubc, and Uca)

Phase voltage (Ua, Ub, and Uc)       Phase voltage (Ua, Ub, and Uc)

Frequency HZ                                 Frequency HZ

Load

Current  IA, IB, IC

Active power kW

Reactive power kvar

Apparent power kVA

Power factor PF

Generator accumulated energy kWh

Output percentage with load %

8. Mains have functions of over/under voltage and lack of phase; Gens have functions of over/under voltage, over/under frequency, over current and over power;


9. Precision measure and display of parameters about engine,

Temp. (WT), °C/ °F

Oil pressure (OP), kPa/psi/bar

Fuel level (FL), % Fuel remains L

Speed (SPD), r/min

Battery Voltage (VB), V

Charger Voltage (VD), V

Accumulative running hours

Accumulative start times


10. Control protection: Automatic start/stop of genset, load transfer(ATS control) and perfect failure display and protection;

11. With ETS, idle speed control, pre-heat control, speed droop/raising control, all of them are relay output;

12. Parameter setting: Allow user to modify setting and store them in internal FLASH memory. The parameters cannot be lost even when power off. All of parameters can be set not only from the front panel, but also use USB interface (or PS485 interface) to adjust them via PC.;

13. Multi sensors of temperature, pressure and fuel level can be used directly, parameters can be defined by user;

14. Multi conditions of crank disconnect (speed, oil pressure, frequency) can be selected;

15. With emergency start function;

16. With flywheel teeth numbers automatic identification function;

17. Power supply range: (8~35)VDC, accommodating to different starting battery volts;

18. All parameters use digital modulation, instead of analog modulation using conventional potentiometer, having improved reliability and stability;

19. With maintenance function. Types (date or running time) can be selected and actions (warning or alarm shutdown) can be set when maintenance time out;

20. Event log, real-time clock, scheduled start & stop pump unit (can be set as start pump unit once a day/week/month whether with load or not);

21. Add rubber gasket between shell and controller screen, the waterproof can reach IP65;

22. Controller is fixed by metal fixing clips;

23. Modular design, flame-retardant ABS shell, embedded mounting, compact structure and easy installation.

PARAMETER LIST


Function ItemParameter
DisplayLCD(132*64)
Operation PanelSilicon Rubber
LanguageChinese & English & Others
Digital Input5
Relay Output6
Analogue Input3
AC System1P2W/2P3W/3P3W/3P4W
Alternator Voltage(15~360)V(ph-N)
Alternator Frequency50/60Hz
kW/Amp Detecting & Display
Programmable InterfaceUSB
RTC & Event Log
Scheduled Start Genset
Maintenance
DC SupplyDC(8~35)V
Case Dimensions(mm)209*166*44
Panel Cutout(mm)186*141
Operating Temp.(-25~+70)℃


If you are interested in 1800KW diesel generating set power distribution cabinet drawing, please click the button below to download the PDF document. It uses SmartGen controller (Model: HGM6110) and Schneider Switcth.

Related Technical Documents
HGM96XX Series Genset Automatic Controller

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us