Home Products News Contact Us
Home > Products > Generators > Starlight > Dingbo STC Series Generator
Dingbo STC Series Generator Dingbo STC Series Generator

Dingbo STC Series Generator

Dingbo STC Three Phase Synchronous Alternator


Model

Power

Current (A)

Extrememly Count

Speed (RPM)

KVA

KW

STC-3

3.75

3

5.4

4

1500

STC-5

6.25

5

9

4

1500

STC-8

10

8

14.4

4

1500

STC-10

12.5

10

18

4

1500

STC-12

15

12

21

4

1500

STC-15

18.75

15

27

4

1500

STC-20

25

20

36

4

1500

STC-24

30

24

43.2

4

1500

STC-30

37.5

30

54

4

1500

STC-40

50

40

72

4

1500

STC-50

62.5

50

90

4

1500

STC-75

93.75

75

135

4

1500

STC-100

125

100

180

4

1500

 

This series of generators is used in villages, towns, construction sites, mountain areas, pastoral areas and other lighting and power three-phase alternating current, also as an emergency power supply.

The generator is rotating magnetic field type, using harmonic excitation system, safe and reliable in use, simple and convenient to maintain.


The alternator is a three-phase four-wire system with neutral point connection, rated voltage of 400 volts, phase voltage of 230 volts, frequency of 50Hz, power factor of 0.8 lags, we and can also provide 60Hz and other voltage values according to the need.


Generator and prime motor can be directly connected or triangular belt connection, and can be rotated positive and reverse continuously. When the rotation speed of the prime mover changes to 3%, the load varies arbitrarily from 0 to 100% cosΦ10-0.8 range, and its constant voltage performance is excellent. When the load is suddenly increased or reduced, it can be adapted quickly and work stably. At the same time, no any starting device is needed to start the no-load rat asynchronous motor with similar capacity.


Dingbo ST Single Phase Synchronous Alternator


This series of single synchronous alternator is mainly used as power supply for small ship lighting, town and household electrical appliances. The generator is drip-proof type, the rotating magnetic field of the salient pole is a self-excited constant voltage type. High quality point material and electrical material are used inside, stator insulation is class E (or B), and the rotor insulation is class B.


The generator adopts the harmonic excitation self-excited constant voltage system, which has the best dynamic characteristics, convenient, reliable and durable in use,  the shape of generator is elegant and easy to maintain, and the installation size adopts the International Electrotechnical Commission (IEC) standard.


The generator has a voltage of 230 or 115 volts, a frequency of 50Hz, and working mode for continuous operation. Generators with 60Hz and other voltage values are also available as required.

The generator is directly connected to the prime mover or connected with a triangular belt. When the rotating speed of the prime motor changes to 5%, the constant voltage performance can be achieved no matter the frequency is from 50Hz to 60Hz, the voltage is 230 volts or 115 volts, and the load is from 0 to 100%.


Model

Power (KW)

Current (A)

Voltage (V)

Power Factor (cos Φ)

Extremely count

Speed (rpm)

Series connection

Series connection

ST-3-2

3

13

230

230

115

1.0

2

3000

ST-5-3

5

21.8

230

230

115

1.0

2

3000

ST-2

2

8.7

230

230

115

1.0

4

1500

ST-3

3

13

230

230

115

1.0

4

1500

ST-5

5

21.8

230

230

115

1.0

4

1500

ST-7.5

7.5

32.6

230

230

115

1.0

4

1500

ST-10

10

43.5

230

230

115

1.0

4

1500

ST-12

12

52.2

230

230

115

1.0

4

1500

ST-15

15

65.3

230

230

115

1.0

4

1500

ST-20

20

87

230

230

115

1.0

4

1500


Dingbo GTF Series Generator
Dingbo TFW Series Generator

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us