DSE7320 MKII is a powerful, new generation Auto Mains Failure genset control module with a highly sophisticated level of new features and functions, presented in the usual DSE user-friendly format. Suitable for a wide variety of single, diesel or gas Genset applications.
Featuring a new Dual Core main processor and extended memory, the module provides faster and more powerful processing power, returning faster operational responses on intensive applications and increased functionality, with data logging facility.
Monitoring an extensive number of engine parameters, the module will display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LED's, remote PC's and via SMS text alerts (with external communication device).
For more types, please contact us
OVERALL SIZE: 245 mm x 184 mm x 51 mm (9.6" x 7.2" x 2.0")
PANEL CUTOUT SIZE: 220 mm x 160 mm (8.7" x 6.3")
MAXIMUM PANEL THICKNESS: 8.0 mm (0.3")
PRODUCT VARIANTS
7320-03 - 7320 MKII Auto Mains Failure Control Module
SPECIFICATION
DC SUPPLY
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
5 V for up to 1 minute
CRANKING DROPOUTS
Able to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.
MAXIMUM OPERATING CURRENT
510 mA at 12 V, 240 mA at 24 V
MAXIMUM STANDBY CURRENT
330 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
GENERATOR & MAINS (UTILITY)
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
25 V to 719 V AC (Ph to Ph)
FREQUENCY RANGE
3.5 Hz to 75 Hz
MAGNETIC PICK UP
VOLTAGE RANGE
+/- 0.5 V to 70 V
FREQUENCY RANGE
10,000 Hz (max)
KEY FEATURES
Comprehensive monitoring of the mains (utility) supply and auto changeover.
4-line back-lit LCD text display
Five key menu navigation
Support for up to three remote display units
Configurable inputs (8)
Configurable analogue / digital inputs (6)
Configurable outputs (8)
Tier 4 CAN engine support.
Integral PLC editor.
Manual fuel pump control.
Power monitoring (kW h, kVAr, kv Ah, kV Ar h), reverse power protection, kW overload protection.
Mains monitoring and automatic start and changeover to generator power in the event of a mains (utility) out of limits or failure.
Configurable CT positioning.
Data logging facility
Customisable power up text and images
Support for 0-10 V & 4-20mA oil pressure senders.