Home Products News Contact Us
Home > Supports > Diesel Engine > Yuchai 6K Series Diesel Power Generation Engines

Yuchai 6K Series Diesel Power Generation Engines

Oct. 18, 2019

Introduction of Yuchai Company

Y&C Engine Co., Ltd. is a large-sized enterprise specializing in the research production and manufacture of the modern and heavy duty engines of  energy conservation and environment protection, and is also the production base of the high end brand products of Yuchai Machinery. The YC6K series motor which is the leading product of the Company possesses the update technical outcome and keeps more than 30 patents. Inheriting 60 years of experienced motor production and relying on experienced international quality management team and top one manufacturing process, our Company is committed to building the world famous heavy-duty power brand.

Precision Manufacturing Achievement World-Class Quantity

1.First-ranking production line with the international advanced level: constant temperature, constant humidity and dust free.

2.103 on-line monitoring and 133 quality characteristic closed-loop control.

3.World-class casting line provides a uniform and consistent high strength.

4.The assemble line comprised of nine robots coordinates with the whole process on-site closed loop quality management system, which is accurate, consistent and reliable.

5.6K series motors undergo 50,000 hours of appraisal, including

Thermal shock test for 600 hours

Overload test for 2,000 hours

Full load test for 3,000 hours

Load cycle test for 5,000 hours

Technical Innovation Combines with World Leading Technology

Bring Together Global Independent Design

6K series motors are the electronic control high-pressure common-rail power generation diesel engine with Chinese propriety brands and intellectual property, being the perfect combination with 60 years' high speed diesel engine manufacturing technology of AVL. ACL team developed 6K just after finished DD13/DD15 design, 6K can compare favorably with DD13/DD15D.

Intelligent Electronic Control

It realizes the electronization of the diesel spray and speed control, and the exhaust after-treatment system makes the emission reach standard of Europe VI and the speed regulation performance is more excellent: the CAN trunk communication meter and the diesel engine control system share the data and can realize the remote control, which is the first-of-its-kind in China.

Integrated Whole Cylinder Head

The cylinder integrates the intake-tube, through the four-valve technology optimized by the international famous research and development institution, the oil and gas mixing is more uniform, the efficiency is higher, the combustion is more complete.

Top-Down Cooling

The cooling liquid is cooled flowing info the engine block from the cylinder head with a high flowing speed. The low-temperature cooling liquid prefers to cool the nose bridge zone of the cylinder head which need cooling most, this make cooling efficiency higher. So, the engines can bear the combustion pressure up to 220bar and the reliability of the engines achieves the historic leap.

High-Strength Vermicular Graphite Cast Iron Components

The main structure adopts the high-strengthen vermicular graphite cast iron structure and the weight of the motors decreases by 15% than that of the traditional motors.


Yuchai diesel generation engine.jpg

6K Series Diesel Generator Power Engines Technical Features

Leading Technology, using the world's most advanced electronically controlled high pressure common rail technology and Yuchai domestic leading electrical calibration technology, fast transient response, excellent speed adjust performance, can satisfy different user' s different requirement for sensitivity and stability;

High reliability, the average life of more than 60,000 hours;

Low emission, low noise, emissions meet EPA3, have better environmental performance.


6K Series Diesel Generating Power Technical Parameters

 

Series

K12

K13

Type

Vertical, in-line, water-cooled, four stroke

Intake way

Turbo charging & inter-cooled

Combustion chamber type

Direct injection necking combustion

Number of cylinder

6

Single Cylinder Valves

4

Cylinder diameter (mm)

129

Piston stroke

155

165

Total displacement (L)

12.155

12.939

Cylinder type

Wet

Compression  ratio

16.5:1

Work order

1-5-3-6-2-4

Maximum power (KW)

382

420

Low fuel consumption (g/kw·h)

≤192

Oil fuel consumption ratio (%)

≤0.15

Crankshaft rotation direction

Counterclockwise

Lubrication

Pressure lubrication and splash lubrication compound

Starting way

Electric start

Oil capacity (L)

28 - 32

Net weight (kg)

1260

1275

 

6K Series Diesel Generating Power Model List


Series

Engine Model

Power (KW)

Rated speed

Inlet

Fuel System

Common

Standby

K10

K1020L-D30

228

252

1500

Turbo   charging & inter-cooled

Electric   control

K12

K1025L-D30

278

306

1500

K1230-D30

335

370

1500

K13

K1232L-D30

356

382

1500

K1335L-D30

389

420

1500

 

6K Series of New Energy Power Generations Technical Features


Low gas consumption: Electronically controlled single point gas injection, electronically controlled high energy independent ignition, electric booster, rarefied combustion technology application, burn more fully, and compared with the gas consumption is lower. 

High reliability: Choose imported gas system components to ensure that the gas machine dedicated components with high reliability. B10 life up to 20,000 hours.

Low noise and environmental protection: Natural gas engine is low noise, small vibration, the emissions keeps the same level with Europe.


6K Series of New Energy Power Generation Technical Parameters


Engine Model

YC6K320LN-D30

YC6K360LN-D31

YC6K360LN-D30

YC6K400LN-D30

YC6K420LN-D30

Engine power (KW)

235

265

265

294

309

Speed (r/min)

1500

1800

Fuel

CNG

LNG

LNG/CNG

Fuel pressure (MPa)

1.5 ~ 0.2

0.5

Fuel   consumption (g/kw·h)

≤195

≤192

≤190

≤196

Gas   Consumption (kw/h)

41

46

45.4

50.3

54

Piston   diameter/ Stroke (mm)

123/155

123/165

129/155

129/165

123/165

Displacement   (L)

12.155

12.939

12.155

12.939

12.939

Compression   ratio

11:1

10:1

11:1

10:1

10:1

The   average piston speed (m/s)

7.75

8.25

7.75

8.25

9.9

MOx   Emission mg/Nm3

≤700

Engine weight (kg)

1150

1220

1150

1210

1210

Ovehaul (h)

≥2400

Steady   timing ratio (%)

≤0.5

Transient   modulation rate (%)

≤10

Oil capacity (L)

32

Oil   consumption g/kwh

0.1

Coolant   capacity (L)

72

Jacket water inlet temper ature

78

Jacket water outlet temperature

86

Air flow (M3/h)

1050

1150

1150

1200

1300

Exhaust flow kg/h

1301

1426

1425

1490

1614

Battery   capacity (AH/V)

160AH/24V

Radiator   cooling area M2

70

78

78

86

92

Intercooler   cooling area M2

13

14

14

16

16

Exhaust   temperature

530

530

520

520

530

Ambient 

temperature

45

Applicable   altitude (mm)

2000


6K Series Commercial Ship Gas Engine Technical Features

Low gas consumption uses electronically control single point injection technology, stable and reliable, the lowest gas consumption in whole country;

Low emissions to meet EPA3;

Wide range of applications can be applied to add liquid LNG vessels, LNG barges, sand pumping ships, and commercial ships.

6K Series Commercial Ship Diesel Engine

Leading technology, developed and designed by Yuchai and Yamaha combined, adopts BOSCH electronically controlled high pressure common rail fuel injection technology, combining the combustion system of Yuchai domestic leading development technology and electronic control system calibration technology, high reliability;

Low oil consumption, applied the electronically controlled high pressure common rail technology, high precision injection, injection pressure is higher than the traditional diesel engine 6 times, four valves advanced technology, advanced air distribution system, make the diesel combustion efficiency greatly improved, which can realize saving more than 10%;

High reliability, the main components uses imported or joint venture brands, guarantee the special engine parts with high reliability. B10 life over 60000 hours.

Engine is small in size, light weight, long life, is a new generation of green environmental protection engine for ship.

6k Series Engineering And Industrial Engine

6K Series Engineering And Industrial Engine Technical Features

Powerful: Large displacement, with long stroke, the engine response fast, strong overloads ability.

Reliable and durable: engine overall structure is strong, using the rear gear roon, wet cylinder liner, high-strength forged steel crankshaft; By adopting the technology of high pressure common rail, the peripheral parts choose the international famous brand, improved reliability.

The province fuel-efficient: patent combustion technology and Yuchai first-class cylinder head airway casting technology in the industry, ensure burning more fully, and fuel efficiency.

Green and Environmental: has same emission level with Europe and America, can reach EPA3 standard.


We are authorized as Yuchai diesel generator OEM/manufacturer/supporting factory and can provide 30KW to 900KW open & silent generator set with Yuchai engine.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us